(FCBC) FLOAT CUM BOOST BATTERY CHARGER by Aditya

DUAL (FCBC) FLOAT CUM BOOST BATTERY CHARGER

In stockcod not available
Phone Number

08042782089

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Gurugram , Gurgaon Division

Gurugram, India, 122001

Description

A Dual FCBC Battery Charger is a highly reliable and intelligent charging system designed to provide a continuous DC power supply for critical equipment. It consists of two identical Float Cum Boost Charger units that operate in parallel. One unit serves as the main charger, while the other acts as a standby to ensure uninterrupted operation in case one unit fails. Each unit operates in two modes: Float mode and Boost mode. In Float mode, the charger supplies a constant voltage to meet the needs of the connected DC load while simultaneously keeping the battery fully charged by compensating for self-discharge. When the battery voltage drops below a preset level, the system automatically switches to Boost mode, providing higher voltage and current to quickly restore the battery charge. Once the battery reaches the desired voltage, the charger automatically disengages the boost charging and reverts to Float mode, ensuring both safety and prolonging the battery's life. It is widely used in power stations, substations, control panels, telecommunication systems, and industrial automation where continuous and fail-safe DC power supply is essential. ---Technical Specs. 1. AC Input : a) Input Voltage : 415Vac 3Phase 4wire b) Frequency : 50Hz 2. DC Output : a) Volt/cell : Float Charge 2.25V(VRLA) Boost Charge 2.30V(VRLA) b) Output Voltage : 24V/48V/110V/220Vdc are available c) Current Rating : 25A/30A/40A/50A/60A/70A/80A/90A/100Amp are available 3. . Cooling Arrangement : 2Nos. Fan Provided 4. Performance : a) Regulation for 0-100% rated load : +/- 1%. b) Ripple content in DC output : With Battery % : <1% pp Without Battery % : <1% pp c) Guaranteed efficiency : > 80% at rated output and nominal input d) Power Factor % : > 0.8 lag at rated output and nominal input. 5. Design Ambient : 0-50 degree Celsius 6. Mounting : Floor Mounting and Free Standing 2 Nos. Channel at Base. 7. Degree of Protection : IP-42 8. Gland Plate : Undrilled, 3mm Thick 9. Location : Indoor 10. Atmosphere : Hot & Dry 11. Cabinet a) Paint Type : Powder-coated paint b) Thickness of Sheet Steel : 1.6mm, 1.8mm, 2.0mm (as per requirement) 12. Size of the unit : 1650 x 900 x 550 mm (H x W x D) the size may vary if the customer requests customization. 13. Indication : a) R-Phase On : 2 Indication b) Y-Phase On : 2 Indication c) B-Phase On : 2 Indication d) Charging On : 2 Indication 14. LED Indication : a) Float Mode : 2 LED Indication b) Boost Mode : 2 LED Indication c) Output U/V : 2 LED Indication d) Output O/V : 2 LED Indication e) DC Earth Fault : 2 LED Indication f) SPP : 2 LED Indication g) DC Output On : 2 LED Indication 15. Metering : a) Type : Digital

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 600/A, 800/5A, 1000/5A, 1250/5A, 1600/5A, 2000/5A or 2500/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 115mm Outer Diameter: 160mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 400/5A, 600/A, 800/5A, 1000/5A, 1250/5A or 1600/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 85mm Outer Diameter: 130mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 300/5A, 400/5A, 500/5A, 600/A, 800/5A, 1000/5A or 1200/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 65mm Outer Diameter: 110mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.