Battery Charger

Battery Charger 12Vdc 10Amp

In stockcod not available
Phone Number

08042781710

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Plot no. 98, Gali No. 5, B Block, Vinay Nagar,

Faridabad, India, 121003

Description

A battery charger is an electrical device that converts alternating current (AC) from the mains into direct current (DC) to recharge batteries safely. It controls the charging process to prevent damage to the battery and includes an auto cut-off feature that stops charging once the battery is fully charged, protecting it from overcharging, overheating, and extending its lifespan. Some chargers also provide trickle or maintenance charging to keep the battery at full charge without causing harm. -Technical Spec. Make : ADITYA Model no : AE-1210 Input Supply : 230vac 1phase 50Hz Output voltage : 12Vdc Current Rating : 10Amp

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 600/A, 800/5A, 1000/5A, 1250/5A, 1600/5A, 2000/5A or 2500/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 115mm Outer Diameter: 160mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 400/5A, 600/A, 800/5A, 1000/5A, 1250/5A or 1600/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 85mm Outer Diameter: 130mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 300/5A, 400/5A, 500/5A, 600/A, 800/5A, 1000/5A or 1200/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 65mm Outer Diameter: 110mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.