Bhubaneswar
08042783190
+919873549984
(FCBC) FLOAT CUM BOOST BATTERY CHARGER by Aditya

1PHASE (FCBC) FLOAT CUM BOOST BATTERY CHARGER

In stockcod not available
Phone Number

08042783190

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Bhubaneswar , Khordha , Central Division

Bhubaneswar, India, 751001

Description

An FCBC Battery Charger, also known as a Float Cum Boost Charger, is an advanced battery charging system designed to efficiently maintain and charge batteries in both standby and load-sharing conditions. It operates in two modes: Float mode and Boost mode, ensuring the battery remains fully charged and ready for use without the risk of overcharging. In Float mode, the charger provides a constant voltage that is slightly lower than the battery’s full charge voltage. This keeps the battery charged continuously and compensates for self-discharge while also supplying power to the connected load. When the battery voltage drops below a preset level—such as after a heavy discharge—the charger automatically switches to Boost mode. In this mode, it delivers a higher voltage and current to quickly restore the battery’s capacity. Once the battery reaches the required voltage level, the system automatically stops boost charging and returns to Float mode, ensuring safety and prolonging battery life. It is commonly used in telecommunication systems, substations, power plants, control panels, and industrial automation setups where continuous DC power supply and reliable battery backup are essential. ---Technical Specs. 1. AC Input : a) Input Voltage : 170-260Vac 1Phase b) Frequency : 50Hz 2. DC Output : a) Volt/cell : Float Charge 2.25V(VRLA) Boost Charge 2.30V(VRLA) b) Output Voltage : 110V/220Vdc are available c) Current Rating : 20A/25A/30A/40Amp are available 3. Type of Cooling : Natural air cooling 4. Performance : a) Regulation for 0-100% rated load : +/- 1%. b) Ripple content in DC output : With Battery % : <1% pp Without Battery % : <1% pp c) Guaranteed efficiency : > 80% at rated output and nominal input d) Power Factor % : > 0.8 lag at rated output and nominal input. 5. Design Ambient : 0-50 degree Celsius 6. Mounting : Floor Mounting and Free Standing 2 Nos. Channel at Base. 7. Location : Indoor 8. Atmosphere : Hot & Dry 9. Cabinet a) Paint Type : Powder-coated paint b) Thickness of Sheet Steel : 1.6mm 10. Size of the unit : 1250 x 510 x 460 mm (H x W x D) 11. Indication : a) Main On b) Charger On 12. LED Indication : a) Float Charge b) Boost Charge c) Output U/V d) Output O/V e) Earth Fault Trip d) DC Output On 13. Metering : a) Type : Digital

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 600/A, 800/5A, 1000/5A, 1250/5A, 1600/5A, 2000/5A or 2500/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 115mm Outer Diameter: 160mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 400/5A, 600/A, 800/5A, 1000/5A, 1250/5A or 1600/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 85mm Outer Diameter: 130mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.

6814772a5d263414004dd4a4 Card 2

product image
CURRENT TRANSFORMER

Available Ratios: 300/5A, 400/5A, 500/5A, 600/A, 800/5A, 1000/5A or 1200/5A (also available in /1A) Burden: 5VA, 10VA, 15VA Accuracy Class: 1.0 or 0.5 Inner Diameter: 65mm Outer Diameter: 110mm Width: 40mm --What is a Current Transformer? A current transformer (CT) is used to measure large currents safely by converting them into smaller, manageable values. -The main side, where the high current is carried, is the primary, and the high current may be hundreds or even thousands of amps. This is typically the primary conductor, or a couple of turns of heavy wire. -The secondary side contains numerous turns of finer wire and carries much less current, usually 1 A or 5 A, but in the same proportion. In simple terms, it transforms a high current in the primary circuit into a lower current in the secondary circuit without changing the ratio. This relationship between primary and secondary current is called the CT ratio. For example, if the CT ratio is 1000:5: • When 1000 A flows in the primary, the secondary current is 5 A. • When 500 A flows in the primary, the secondary current is 2.5 A. Due to this reason meters and protection relays are attached on the secondary side. They are able to measure and monitor the system without being at risk of being exposed to high currents. --Uses of Current Transformer (CT) : 1. Used to measure high current safely using standard meters. 2. Supports protection relays in detecting faults and abnormal conditions 3. Provides electrical isolation to protect instruments and operators 4. Common in electrical distribution systems, switchgear and electrical panels.