Bhubaneswar
08042783190
+919873549984

alarm annunciator

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of thirty lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F30, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 30 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 15VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 288 (H) * 144 (V) * 150 (D) mm Cut Out size : 284 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of twenty four lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F24, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 24 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 15VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 432 (H) * 144 (V) * 150 (D) mm Cut Out size : 424 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of twenty four lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F24, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 24 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 15VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 216 (H) * 144 (V) * 150 (D) mm Cut Out size : 212 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of twenty lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F20, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 20 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 15VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 216 (H) * 144 (V) * 150 (D) mm Cut Out size : 212 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of eighteen lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F18, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 18 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 14VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 216 (H) * 144 (V) * 150 (D) mm Cut Out size : 212 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of sixteen lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F16, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 16 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 14VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 288 (H) * 144 (V) * 150 (D) mm Cut Out size : 284 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of sixteen lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F16, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 16 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 14VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 144 (H) * 144 (V) * 150 (D) mm Cut Out size : 141 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of twelve lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F12, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 12 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 14VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 216 (H) * 144 (V) * 150 (D) mm Cut Out size : 212 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of twelve lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F12, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 12 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 14VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 144 (H) * 144 (V) * 150 (D) mm Cut Out size : 141 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of eight lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F8, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 8 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 10VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Physical size of the unit : Overall Size : 192 x 96 x 140 mm Cut Out size : 189 x 92mm

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of eight lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F8, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 8 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 10VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Size cutout : 140mm * 140mm 9. Physical size of the unit : Overall Size : 144 (H) * 144 (V) * 150 (D) mm Cut Out size : 141 (H) mm * 141 (V) mm.

6814772a5d263414004dd4a4 Card 2

product image
Alarm Annunciator

The ADITYA Annunciator panel consists of a set of eight lights that serve as a centralised indicator of the status of equipment or systems in industrial processes, buildings, or other installations. These annunciators are designed to function effectively under challenging conditions, including system vibrations, high temperatures, and dusty environments. The integration of microprocessor technology ensures high accuracy in performance. -Principle of operation : During operation, if any fault occurs, the corresponding window will start flashing, the internal buzzer will sound, and the external hooter’s C-NO contacts will close. In contrast, the trip contacts become energised, meaning the C-NOs will close and the C-NC contacts will open. Pressing the “Acknowledge“ (Ack) button will stop the flashing light, make it steady, silence the internal buzzer, and open the external hooter contact, effectively turning the external hooter off. After the fault has been cleared, pressing the “Reset“ button will restore the system to normal operating conditions. This procedure also applies to faults F2 to F8, where the outputs will be monitored accordingly. -Technical Specifications : 1. Supply Voltage : 12Vdc, 24Vdc, 48Vdc, 110Vdc, 110Vac, 230Vac or 90-260Vac/dc 2. No. of input Faults : 8 ( Faults should be potential free) 3. Output Contact rating : 5A @ 230Vac. 4. Flashing Duty cycle : 1-1.2 sec. 5. Power consumption on standby : 3VA max. 6. Power consumption on all faults : 10VA max. 7. Insulation between output contacts & internal circuit : > 10 Mohm. 8. Size cutout : 140mm * 140mm 9. Physical size of the unit : Overall Size : 72 (H) * 144 (V) * 150 (D) mm Cut Out size : 70 (H) mm * 140 (V) mm.

Phone Number

08042783190

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Bhubaneswar , Khordha , Central Division

Bhubaneswar, India, 751001